Sound absorption testing in the reverberation room

Traceable — not in accredited scope

Sound absorption is measured by putting the material in a reverberation room and recording how much faster sound decays with it there than without it. That is the whole method, and it is why the number depends as much on how the specimen is mounted as on what it is made of.

What you get back

Materials and products we test

Mounting changes the answer

Mounting is not a detail. The same absorber tested flat against a rigid backing and again with an air cavity behind it can differ by several tenths of an absorption coefficient at low frequency — enough to move an NRC by a full step. ASTM C423 mountings A, E-400 and J and the ISO 354 equivalents describe genuinely different products as far as the result is concerned. Tell us the mounting the material will actually be installed in, and if your specification names one, quote it to us. A figure published without its mounting condition is not comparable to anything.

Turnaround and logistics

Typical turnaround
About two weeks from receipt of a complete specimen and an agreed scope
Urgent work
An urgent route is available — tell us the date you are working to at enquiry, not after booking
Before you ship
Confirm specimen size, mounting and packing first — see sample requirements
Report language
Reports issued in English; correspondence in Thai or English
How an absorption test actually runs in the reverberation room, from specimen to reported coefficient.

Random-incidence absorption on a full-size specimen in the reverberation room. Reported per one-third-octave band, with the single-number rating your specifier asked for: αw and absorption class to ISO 11654, or NRC and SAA to ASTM C423.

What we test

Mounting changes the number more than the material does

The same 50 mm absorber mounted directly against a rigid backing (Type A) and mounted with a 200 mm air gap (Type E-200) can differ by several tenths of an absorption coefficient at low frequency. Neither result is wrong. If you publish an αw obtained with an air gap and your customer installs the product flat against concrete, you have a warranty problem, not a laboratory problem. Tell us how the product is actually installed and we will test it that way.

Reverberation room

Specimen area
10–12 m² per ISO 354
Mounting options
Type A (direct), Type E-200 (200 mm air gap), Type J (suspended grid)
Frequency range
100–5,000 Hz, one-third-octave bands
Room qualification
ISO 354 Annex A
Reported quantities
αs per band, αp, αw + class (ISO 11654), NRC + SAA (ASTM C423)